PID: BS-040104-A06 UID: 002-01-1-UVC/T-M-AR-0 Ostatnia aktualizacja: 04.01.2024 10:53

Komora do PCR Biosan UVC/T-M-AR star star star star star

  • Twoja ocena:

    star_border star_border star_border star_border star_border

  • Czas dostawy: na zamówienie.
  • Ilość sztuk:
    szt.
  • Cena brutto 16315.95pln
  • Cena netto 13265.00pln
Array
(
    [id] => 5914
    [0] => 5914
    [rel] => 5773
    [1] => 5773
    [title] => Komora do PCR Biosan UVC/T-M-AR
    [2] => Komora do PCR Biosan UVC/T-M-AR
    [names] => 
    [3] => 
    [type] => products
    [4] => products
    [status] => 1
    [5] => 1
    [sum_views] => 5887
    [6] => 5887
    [template] => 2
    [7] => 2
    [menu] => 
    [8] => 
    [counter] => 0
    [9] => 0
    [time] => 2024-01-04 10:53:58
    [10] => 2024-01-04 10:53:58
    [sub_templates] => 0
    [11] => 0
    [catalog] => 0
    [12] => 0
    [blink] => 0
    [13] => 0
    [alias] => komora-do-pcr-biosan-uvct-m-ar
    [14] => komora-do-pcr-biosan-uvct-m-ar
    [pozycja] => 
    [15] => 
    [kolor] => 0
    [16] => 0
    [ccs_id] => 14
    [17] => 14
    [iid] => 5914
    [18] => 5914
    [sdesc] => 

Komora do PCR seria UVC/T-M-AR zaprojektowana do pracy czystej z próbkami DNA zapewnia ochronę przed kontaminacją.

[19] =>

Komora do PCR seria UVC/T-M-AR zaprojektowana do pracy czystej z próbkami DNA zapewnia ochronę przed kontaminacją.

[desc] =>

UVC/T-M-AR to komora zaprojektowana do czystej pracy z próbkami DNA. Komora zapewnia ochronę przeciwko kontaminacji. Model UVC/T-M-AR jest modelem nastołowym, wykonanym z metalowej ramy i powierzchni roboczej ze stali nierdzewnej.

Komora jest wyposażona w otwartą lampę UV zainstalowaną w górnej części komory. Promieniowanie UV z otwartej lampy dezynfekuje powierzchnię roboczą dezaktywując fragmenty DNA/RNA w ciągu 15-30 min ekspozycji. Cyfrowy timer kontroluje czas naświetlania. Lampa światła białego zapewnia właściwe oświetlenie powierzchni roboczej.

Komora wyposażona jest w przepływową lampę antybakteryjną UV, która zapewnia ciągła dekontaminację wewnątrz komory w czasie pracy. Lampa ta jest zalecana do pracy z amplikonami DNA/RNA.

Recyrkulator UV zawiera lampę, wentylator i filtry przeciwkurzowe umieszczone w specjalnej obudowie, która sprawia że użytkownik pracujący w komorze jest chroniony przed promieniowaniem UV. Recyrkulator zwiększa maksymalną gęstość światła UV, co czyni go dostatecznie skutecznym do dezaktywacji DNA/RNA. Recyrkulator UV przetwarza 100 objętości komory na godzinę, tworząc aseptyczne warunki pracy wewnątrz komory.

Specjalnie dedykowany stół T-4 (z kółkami z blokadą) z szufladą jest dostępny na zamówienie.

Właściwości:

  • bezozonowa dezynfekcja promieniami UV,
  • lampy UV o długiej żywotności (szacunkowo do 9000 godz.),
  • automatyczne wyłączanie otwartej lampy UV, gdy okno frontowe jest uniesione,
  • bakteriobójcza przepływowa lampa UV zapewnia stałą dekontaminację wewnątrz komory w czasie pracy,  
  • ściany odporne na uszkodzenia,
  • niski poziom hałasu i zużycia energii,
  • stół do instalacji komory (opcjonalnie),
  • komora z lampą przepływową UV jest rozwiązaniem opatentowanym przez Biosan.
[20] =>

UVC/T-M-AR to komora zaprojektowana do czystej pracy z próbkami DNA. Komora zapewnia ochronę przeciwko kontaminacji. Model UVC/T-M-AR jest modelem nastołowym, wykonanym z metalowej ramy i powierzchni roboczej ze stali nierdzewnej.

Komora jest wyposażona w otwartą lampę UV zainstalowaną w górnej części komory. Promieniowanie UV z otwartej lampy dezynfekuje powierzchnię roboczą dezaktywując fragmenty DNA/RNA w ciągu 15-30 min ekspozycji. Cyfrowy timer kontroluje czas naświetlania. Lampa światła białego zapewnia właściwe oświetlenie powierzchni roboczej.

Komora wyposażona jest w przepływową lampę antybakteryjną UV, która zapewnia ciągła dekontaminację wewnątrz komory w czasie pracy. Lampa ta jest zalecana do pracy z amplikonami DNA/RNA.

Recyrkulator UV zawiera lampę, wentylator i filtry przeciwkurzowe umieszczone w specjalnej obudowie, która sprawia że użytkownik pracujący w komorze jest chroniony przed promieniowaniem UV. Recyrkulator zwiększa maksymalną gęstość światła UV, co czyni go dostatecznie skutecznym do dezaktywacji DNA/RNA. Recyrkulator UV przetwarza 100 objętości komory na godzinę, tworząc aseptyczne warunki pracy wewnątrz komory.

Specjalnie dedykowany stół T-4 (z kółkami z blokadą) z szufladą jest dostępny na zamówienie.

Właściwości:

  • bezozonowa dezynfekcja promieniami UV,
  • lampy UV o długiej żywotności (szacunkowo do 9000 godz.),
  • automatyczne wyłączanie otwartej lampy UV, gdy okno frontowe jest uniesione,
  • bakteriobójcza przepływowa lampa UV zapewnia stałą dekontaminację wewnątrz komory w czasie pracy,  
  • ściany odporne na uszkodzenia,
  • niski poziom hałasu i zużycia energii,
  • stół do instalacji komory (opcjonalnie),
  • komora z lampą przepływową UV jest rozwiązaniem opatentowanym przez Biosan.
[file] => 3829 [21] => 3829 [link] => 0 [22] => 0 [odkiedy] => 2018-04-16 12:00:00 [23] => 2018-04-16 12:00:00 [dokiedy] => 2999-04-16 23:59:00 [24] => 2999-04-16 23:59:00 [emituj] => 1 [25] => 1 [pluralllg] => [26] => [ccs_field_01] =>

Modele

  • UVC/T-M-AR
[27] =>

Modele

  • UVC/T-M-AR
[ccs_field_02] => ISO9001, CE [28] => ISO9001, CE [ccs_field_03] =>

Specyfikacja

MODEL UVC/T-M-AR
Materiał ścian

tylna: stal nierdzewna
boczne i frontowa: szkło (EUROGLASS, Niemcy)

Powierzchnia robocza stal nierdzewna
Wbudowana lampa UV otwarta UV, wbudowana lampa bakteriobójcza 1 x 25 W, TUV 25W 1SL/25
Typ promieniowania UV [nm] bezozonowa λ=253,7
Poziom promieniowania UV [mW / cm2 /s] 18
Timer cyfrowy timer ustawiania bezpośredniej ekspozycji UV 1 min – 24 godz. (krok co 1 min.) / praca ciągła
Recyrkulator promieni UV [W] 1 x 25 (skuteczność >99% / godz.)
Lampa światła białego [W] 1 x 15 (TLD)
Ściany boczne ze szkła o grubości [mm] 4
Grubość górnej części okna frontowego [mm] 8
Grubość osłony okna frontowego [mm] 4
Przepuszczalność optyczna [%] 95
Filtr ochronny przed promieniami UV [%] skuteczność >96 z filtrem UV
Wymiary powierzchni roboczej [mm] 645 x 490
Funkcje bezpieczeństwa automatyczne wyłączenie otwartej lampy UV, kiedy okno jest otwarte
Gniazda w komorze port na przewody elektryczne,
wbudowane gniazdo max. 1000 W
Wymiary (W x D x H) (mm] 700 x 580 x 555
Zasilanie [V / Hz / W] 230 / 50 / 67
Waga netto / brutto [kg] 28,8 / 39
[29] =>

Specyfikacja

MODEL UVC/T-M-AR
Materiał ścian

tylna: stal nierdzewna
boczne i frontowa: szkło (EUROGLASS, Niemcy)

Powierzchnia robocza stal nierdzewna
Wbudowana lampa UV otwarta UV, wbudowana lampa bakteriobójcza 1 x 25 W, TUV 25W 1SL/25
Typ promieniowania UV [nm] bezozonowa λ=253,7
Poziom promieniowania UV [mW / cm2 /s] 18
Timer cyfrowy timer ustawiania bezpośredniej ekspozycji UV 1 min – 24 godz. (krok co 1 min.) / praca ciągła
Recyrkulator promieni UV [W] 1 x 25 (skuteczność >99% / godz.)
Lampa światła białego [W] 1 x 15 (TLD)
Ściany boczne ze szkła o grubości [mm] 4
Grubość górnej części okna frontowego [mm] 8
Grubość osłony okna frontowego [mm] 4
Przepuszczalność optyczna [%] 95
Filtr ochronny przed promieniami UV [%] skuteczność >96 z filtrem UV
Wymiary powierzchni roboczej [mm] 645 x 490
Funkcje bezpieczeństwa automatyczne wyłączenie otwartej lampy UV, kiedy okno jest otwarte
Gniazda w komorze port na przewody elektryczne,
wbudowane gniazdo max. 1000 W
Wymiary (W x D x H) (mm] 700 x 580 x 555
Zasilanie [V / Hz / W] 230 / 50 / 67
Waga netto / brutto [kg] 28,8 / 39
[ccs_field_04] =>

Wyposażenie opcjonalne

  • stół T-4 (800 x 600 x 750 mm),
  • półka P-5 (230 x 140 x 50 mm) na 5 pipet,
  • półka F-1 (400 x 140 x 50 mm) na szkło laboratoryjne, reagenty, próbki.
[30] =>

Wyposażenie opcjonalne

  • stół T-4 (800 x 600 x 750 mm),
  • półka P-5 (230 x 140 x 50 mm) na 5 pipet,
  • półka F-1 (400 x 140 x 50 mm) na szkło laboratoryjne, reagenty, próbki.
[ccs_field_05] => https://www.youtube.com/embed/GPa5GATlqgI?enablejsapi=1 [31] => https://www.youtube.com/watch?v=GPa5GATlqgI [ccs_field_06] => [32] => [ccs_field_07] => BS-040104-A06 [33] => BS-040104-A06 [ccs_field_08] => 0 [34] => 0 [ccs_field_09] => 0 [35] => 0 [ccs_field_10] => 002-01-1-UVC/T-M-AR-0 [36] => 002-01-1-UVC/T-M-AR-0 [ccs_field_11] => [37] => [ccs_field_12] => [38] => [ccs_field_13] => [39] => [ccs_field_99] => 24 [40] => 24 [ccs_field_100] => 24 [41] => 24 [ccs_field_101] => 1 [42] => 1 [43] => 5914 [cena_netto] => 13265.00 [44] => 13265.00 [cena_brutto] => 16315.95 [45] => 16315.95 [prom_netto] => 0.00 [46] => 0.00 [prom_brutto] => 0.00 [47] => 0.00 [vat] => 23 [48] => 23 [kod] => 002-01-1-UVC/T-M-AR-0 [49] => 002-01-1-UVC/T-M-AR-0 [magazyn] => 0 [50] => 0 [magazyn_on] => 0 [51] => 0 [producent] => 5848 [52] => 5848 [waga] => 0 [53] => 0 [dostawa] => 2,4 [54] => 2,4 [promo] => 0 [55] => 0 [modul] => [56] => [dostepny] => 2 [57] => 2 [count_sale] => 0 [58] => 0 [rabat] => 0 [59] => 0 [proa3m] => 0 [60] => 0 [cena_brutto_waluta] => 0.00 [61] => 0.00 [waluta_symbol] => 0 [62] => 0 [state] => new [63] => new [producturl] => [64] => )
lub
Zapytaj o wynajem od PLN netto

OPIS OGÓLNY

UVC/T-M-AR to komora zaprojektowana do czystej pracy z próbkami DNA. Komora zapewnia ochronę przeciwko kontaminacji. Model UVC/T-M-AR jest modelem nastołowym, wykonanym z metalowej ramy i powierzchni roboczej ze stali nierdzewnej.

Komora jest wyposażona w otwartą lampę UV zainstalowaną w górnej części komory. Promieniowanie UV z otwartej lampy dezynfekuje powierzchnię roboczą dezaktywując fragmenty DNA/RNA w ciągu 15-30 min ekspozycji. Cyfrowy timer kontroluje czas naświetlania. Lampa światła białego zapewnia właściwe oświetlenie powierzchni roboczej.

Komora wyposażona jest w przepływową lampę antybakteryjną UV, która zapewnia ciągła dekontaminację wewnątrz komory w czasie pracy. Lampa ta jest zalecana do pracy z amplikonami DNA/RNA.

Recyrkulator UV zawiera lampę, wentylator i filtry przeciwkurzowe umieszczone w specjalnej obudowie, która sprawia że użytkownik pracujący w komorze jest chroniony przed promieniowaniem UV. Recyrkulator zwiększa maksymalną gęstość światła UV, co czyni go dostatecznie skutecznym do dezaktywacji DNA/RNA. Recyrkulator UV przetwarza 100 objętości komory na godzinę, tworząc aseptyczne warunki pracy wewnątrz komory.

Specjalnie dedykowany stół T-4 (z kółkami z blokadą) z szufladą jest dostępny na zamówienie.

Właściwości:

  • bezozonowa dezynfekcja promieniami UV,
  • lampy UV o długiej żywotności (szacunkowo do 9000 godz.),
  • automatyczne wyłączanie otwartej lampy UV, gdy okno frontowe jest uniesione,
  • bakteriobójcza przepływowa lampa UV zapewnia stałą dekontaminację wewnątrz komory w czasie pracy,  
  • ściany odporne na uszkodzenia,
  • niski poziom hałasu i zużycia energii,
  • stół do instalacji komory (opcjonalnie),
  • komora z lampą przepływową UV jest rozwiązaniem opatentowanym przez Biosan.

Specyfikacja

MODEL UVC/T-M-AR
Materiał ścian

tylna: stal nierdzewna
boczne i frontowa: szkło (EUROGLASS, Niemcy)

Powierzchnia robocza stal nierdzewna
Wbudowana lampa UV otwarta UV, wbudowana lampa bakteriobójcza 1 x 25 W, TUV 25W 1SL/25
Typ promieniowania UV [nm] bezozonowa λ=253,7
Poziom promieniowania UV [mW / cm2 /s] 18
Timer cyfrowy timer ustawiania bezpośredniej ekspozycji UV 1 min – 24 godz. (krok co 1 min.) / praca ciągła
Recyrkulator promieni UV [W] 1 x 25 (skuteczność >99% / godz.)
Lampa światła białego [W] 1 x 15 (TLD)
Ściany boczne ze szkła o grubości [mm] 4
Grubość górnej części okna frontowego [mm] 8
Grubość osłony okna frontowego [mm] 4
Przepuszczalność optyczna [%] 95
Filtr ochronny przed promieniami UV [%] skuteczność >96 z filtrem UV
Wymiary powierzchni roboczej [mm] 645 x 490
Funkcje bezpieczeństwa automatyczne wyłączenie otwartej lampy UV, kiedy okno jest otwarte
Gniazda w komorze port na przewody elektryczne,
wbudowane gniazdo max. 1000 W
Wymiary (W x D x H) (mm] 700 x 580 x 555
Zasilanie [V / Hz / W] 230 / 50 / 67
Waga netto / brutto [kg] 28,8 / 39

Modele

  • UVC/T-M-AR

Indeksy produktu

Specyfikacja

MODEL UVC/T-M-AR
Materiał ścian

tylna: stal nierdzewna
boczne i frontowa: szkło (EUROGLASS, Niemcy)

Powierzchnia robocza stal nierdzewna
Wbudowana lampa UV otwarta UV, wbudowana lampa bakteriobójcza 1 x 25 W, TUV 25W 1SL/25
Typ promieniowania UV [nm] bezozonowa λ=253,7
Poziom promieniowania UV [mW / cm2 /s] 18
Timer cyfrowy timer ustawiania bezpośredniej ekspozycji UV 1 min – 24 godz. (krok co 1 min.) / praca ciągła
Recyrkulator promieni UV [W] 1 x 25 (skuteczność >99% / godz.)
Lampa światła białego [W] 1 x 15 (TLD)
Ściany boczne ze szkła o grubości [mm] 4
Grubość górnej części okna frontowego [mm] 8
Grubość osłony okna frontowego [mm] 4
Przepuszczalność optyczna [%] 95
Filtr ochronny przed promieniami UV [%] skuteczność >96 z filtrem UV
Wymiary powierzchni roboczej [mm] 645 x 490
Funkcje bezpieczeństwa automatyczne wyłączenie otwartej lampy UV, kiedy okno jest otwarte
Gniazda w komorze port na przewody elektryczne,
wbudowane gniazdo max. 1000 W
Wymiary (W x D x H) (mm] 700 x 580 x 555
Zasilanie [V / Hz / W] 230 / 50 / 67
Waga netto / brutto [kg] 28,8 / 39

Modele

  • UVC/T-M-AR

T-4 mobilny stół do UVC/T-AR, UVC/T-M-AR oraz UVT-B-AR

T-4 mobilna podstawa z półką przeznaczona dla komór do PCR.

  • Cena brutto od 3431.70pln
  • Cena netto od 2790.00pln
szczegóły

Półka P-5 na pipety do komory do PCR Biosan

Półka na pięć pipet do komór UVT-B-AR, UVC/T-M-AR oraz UVT-S-AR.

  • Cena brutto od 393.60pln
  • Cena netto od 320.00pln
szczegóły

Półka F-1 do komory do PCR Biosan

Półka do komór UVT-B-AR, UVC/T-M-AR oraz UVT-S-AR.

  • Cena brutto od 369.00pln
  • Cena netto od 300.00pln
szczegóły

Wyposażenie opcjonalne

  • stół T-4 (800 x 600 x 750 mm),
  • półka P-5 (230 x 140 x 50 mm) na 5 pipet,
  • półka F-1 (400 x 140 x 50 mm) na szkło laboratoryjne, reagenty, próbki.
PRZEDŁUŻONA GWARANCJA - DOSTĘPNA

1 GWARANCJA URZĄDZENIA

Urządzenie Komora do PCR Biosan UVC/T-M-AR posiada standardową 24 mies. gwarancję.

2 PRZEDŁUŻENIE GWARANCJI URZĄDZENIA

Dla wybranego urządzenia dostępna jest opcja przedłużonej gwarancji. Dla urządzeń o standardowej gwarancji 24 miesięcy,
MOŻLIWE JEST PRZEDŁUŻENIE JEJ DO 36 MIESIĘCY.

Zapoznaj się z warunkami przedłużenia

3 GWARANCJA NIESTANDARDOWA

Jeśli jesteś zainteresowany innymi / nietypowymi warunkami gwarancji, prosimy o kontakt z naszymi handlowcami.

Przejdź do kontaktu Wyślij zapytanie na e-mail

Czym jest wynajem długoterminowy?

Usługa wynajmu długoterminowego przeznaczona jest wyłącznie dla instytucji publicznych oraz firm posiadających dofinansowanie ze środków unijnych lub grantów NCBR. Nie chcesz lub nie możesz kupić urządzenia, masz grant - nie kupuj - wynajmij! Elastyczna forma finansowania urządzeń laboratoryjnych, dostępna w okresie od 12 do 36 miesięcy. Atrakcyjne warunki współpracy i minimum formalności. Skontaktuj się z nami lub zapytaj o szczegóły swojego handlowca. Więcej informacji na temat usługi w regulaminie.

Chcę wynająć urządzenie - co robić?

To proste! Poniższy kalkulator prezentuje przykładowe / orientacyjne koszty najmu urządzenia(1). Po wybraniu interesującego cię okresu wynajmu naciśnij “zapytaj o wynajem”. Na wskazany w formularzu adres e-mail prześlemy szczegółową ofertę dla tego urządzenia.

Czas trwania umowy:

24 mies.

Kwota mies. zobowiązania netto(2):

od 0.00 PLN netto

12mies. 24mies. 36mies.
  1. Przedstawiona oferta cenowa ma charakter informacyjny i nie stanowi oferty handlowej w rozumieniu Art. 66 par. 1 Kodeksu Cywilnego.
  2. Przedstawione ceny są cenami orientacyjnymi i mogą różnić się od finalnego kosztu usługi. Wypełnij formularz ofertowy lub skontaktuj się z Biogenet, by poznać finalny koszt usługi wynajmu.
  3. Na wskazany w formularzu adres e-mail prześlemy wstępną ofertę najmu wybranego przez Ciebie urządzenia. Upewnij się, że podany adres jest prawidłowy.
  • Ceny LOCO magazyn Biogenet.
  • Dane techniczne i cena mogą ulec zmianie bez uprzedzenia.
  • UWAGA! W przypadku produktu „na zamówienie” mogą być doliczone dodatkowe koszty transportu. Prosimy o kontakt z naszym biurem handlowym.

Najnowszy katalog ofertowy 2023 - 2024

Menu
 
Kategorie produktów
Zawartość cnb_search
Zawartość cnb_user
Zawartość cnb_mail
Zawartość cnb_call